Self adjusting load sensor automatically adjusts from minimum to maximum output.
Overload Protection / Auto shutdown feature
Can be mounted directly to metal.
No mercury migration. Weight: 1.5 lbs.
Output current: 30mA
Input voltage: 12 volts
11" GTO cable; 12" 12vt out wires, the 12vt Red POS (+) wire features an inline fuse
Size: 5 1/4"L x 2"W x 1 1/2"H
4500V Output Voltage self adjusts from 2 to 4.5 KVt
FOOTAGE
ARGON 15mm/14', 13mm/12', 12mm/11', 10mm/8'
NEON 15mm/12', 13mm/11', 12mm/10', 10mm/7'
*Actual footage will vary due to amount and placement of GTO wire
7500V Output Voltage self adjusts from 2 to 7.5 KVt
A 12 volt neon transformer beefed up for larger projects.
FOOTAGE
ARGON 15mm/23', 13mm/20', 12mm/15', 10mm/12'
NEON 15mm/19' 13mm/17', 12mm/16', 10mm/11'
*Actual footage will vary due to amount and placement of GTO wire
Warranty: One year.
Installation
This power supply unit is for INDOOR USE. (May be used for outdoor applications if mounted in metal weatherproof enclosure/box.)
This unit can be installed on either metallic or non-metallic surfaces.
Always provide adequate ventilation to power supply.
Keep overall length of GTO leads under 6 feet (2m).
Always keep a minimum of 1 inch between GTO leads and any metallic surfaces.
When using multiple power supplies on one sign, be sure to keep at least 3 inches between each unit.
Never cross GTO leads.
Never run GTO leads across the power supply.
Keep GTO leads as equal in length as possible.
Always keep installation in conformity with all local electric codes.
Modification of any type including cutting/removing of AC cord, tampering with on/off switch or tampering with casing will void any existing product warranty. NO EXCEPTIONS.
Transformer Leads
High voltage leads: approx. 11" long.
Black Neg (-) 12vt input wire: approx. 12" long.
Red POS (+) 12vt input wire: approx. 8" long.
Red wire includes in-line fuse for added safety.
White external controller wire: approx. 13" long.
Note: The white input wire is designed for an external controller. The manufacturer does not offer a controller and this function is not supported. On most, if not all installations, the white wire is not connected.